Paint plant, machinery & formulation consultancy, India and worldwide

Non-Shrink Grout Manufacturing: Expansion, Flow & Testing

How cementitious non-shrink grouts are formulated to flow, expand slightly and reach strength, and which tests prove them.

01Introduction

In short: non-shrink grout is a flowable, high-strength cementitious grout used under machine bases, anchor bolts and columns. It uses cement, graded fine aggregate, an expansion system and a powder superplasticiser. Quality is proven by flow, expansion and strength tests, for example under ASTM C1107, and the plant must dose additives very accurately.

Non-shrink grouts are specification-driven products sold to contractors and industrial plants. Failure means a loose machine base, so buyers want data.

Accurate batching and a clean line are more important than machine size.

02What Is Non-Shrink Grout?

The grout needs to flow into tight spaces without bleeding or segregating, then expand slightly to remain in contact with the base plate, and then reach high early and final strength. Expansion can come from aluminium powder, calcium sulfoaluminate or other systems.

ASTM C1107 covers packaged dry hydraulic-cement grout (non-shrink), and other standards apply in other markets.

03Applications & End Uses

  • Machine foundation base plates
  • Anchor bolts and rebar fixing
  • Precast joints and column bases
  • Bridge bearings and structural repairs

04Types, Grades & Variants

TypeFeaturesUse
Flowable cementitious groutPourable, high strengthBase plates
Pourable plastic groutStiffer, for larger gapsColumns
Dry pack groutVery stiffSmall gaps
Epoxy groutChemical resistanceSpecial foundations

05Raw Materials & Their Functions

Raw materialFunctionSelection note
Cement (OPC or rapid)BinderConsistent, fresh
Graded fine sand (0 to 1 mm)AggregateNarrow grading, dry
Expansion agentCompensate shrinkageType and dose by trial
Powder superplasticiser (PCE, melamine)Flow with low waterEfficiency and compatibility
Silica fume (optional)Strength, cohesionDosing and handling
Defoamer, anti-bleed additivesStabilitySmall doses

06Formulation Guidance

Non-shrink grouts have low water demand and high cement plus fine aggregate content.

Component groupIndicative rangeWhy it matters
Cement25% to 40%Binder
Fine aggregate50% to 70%Body
Expansion and plasticiser0.5% to 3%Expansion, flow
Silica fume and others0% to 8%Strength
Ranges are indicative starting points for trials, not a ready formula. Final proportions depend on your raw materials, equipment, target cost and the standard you need to meet.

07Manufacturing Process

  1. Dry and screen aggregateVery low moisture.
  2. Pre-blend additivesSmall premix.
  3. Weigh accuratelyLow tolerance.
  4. MixRibbon or paddle mixer.
  5. Test flow and expansion
  6. PackMoisture-proof bags, small to 25 kg.

08Machinery & Equipment

MachineRole in this product
Ribbon BlenderMixer
Powder Mixing & Dry Mortar MixerPowder mixer
Dry Mix Plant MachineryFull line

09Plant Layout, Space & Utilities

  • Precise scales for additives
  • Moisture-proof packing
  • Testing cubes and flow cone

10Quality Control & Testing

Test or checkWhat it tells youMethod or reference
FlowPourabilityFlow cone or flow table
ExpansionNon-shrink behaviourHeight change method
Compressive strengthEarly and 28-dayCubes
Bleeding and segregationStabilityStandard test
Initial and final setWorking timeVicat

11Common Production Problems & Fixes

ProblemLikely causeWhat to do
BleedingWater too high or no stabiliserAdjust
Shrinkage cracksWrong expansion systemRe-formulate
Low flowPlasticiserIncrease dose
LumpsMoistureBetter packing
Strength lower than claimCement variationTest cement

12Capacity, Cost & Investment Factors

Quality, not volume, defines this product:

  • Additive cost
  • Testing equipment
  • Technical sales
  • Packaging

13How IPCS Supports This Project

  • Formulation and test plan
  • Specification data sheets
  • Batching procedure

Scope, deliverables and timelines are written into a quotation after we understand your products, capacity, site and budget. Machine details are indicative and are finalised against your product.

14Frequently Asked Questions

What is non-shrink grout?

A grout that does not shrink and sometimes expands slightly so it stays in contact with the base plate.

What standards are used?

ASTM C1107 is one; check local specifications.

Is it easy to make?

The mixing is easy; accuracy and testing are the challenge.

Can I use it for anchor bolts?

Yes, with grades designed for it.

What is the shelf life?

Months in sealed bags.

How can IPCS help me start non-shrink grout manufacturing?

IPCS confirms the product range and capacity, plans the process and machines, tunes the formulation with your raw materials, sets up the laboratory, trains your team and supports the first batches. The written quote states exactly what is included.

Get Technical Consultation

Tell us what you want to make. A paint technologist replies with next steps within one working day.

Your details are used only to reply to this enquiry. Direct line: +91 82104 79182.

Planning a paint or dry mix plant?Get Technical Consultation